HomeSSM73671 Attachm · JAGUAR
JAGUAR

SSM73671 Attachm

Manufacturer communications

Publication date
2017-12-06
Received by NHTSA
2018-01-22
NHTSA record numbers
10127288 · 10127582

Multiple filings of the same bulletin are grouped here; original record numbers remain available.

Manufacturer summary

Original wording in English

A Customer may report one or more of: ?Lack of power ?Restricted performance displayed on Instrument Cluster (IC) ?Malfunction Indicator Light (MIL) appears on Instrument Cluster (IC). One or more of the following DTC?s may also be logged within the Powertrain Control Module (PCM) P0100-38 - Mass or Volume Air Flow Sensor "A" Circuit signal frequency incorrect P0111-84 - Intake Air Temperature Sensor 1 Circuit Range/Performance Bank 1 signal below allowable range P0113-00 - Intake Air Temperature Sensor 1 Circuit High Bank 1 no sub type information P2178-00 - System Too Rich Off Idle Bank 1 no sub type information P0299-00 - Turbocharger/Supercharger "A" Underboost Condition no sub type information

NHTSA manufacturer communications ↗

Reported code forms

Manufacturer wording

Source wording can vary by vehicle and suffix. It is shown as written, not as a universal diagnosis.

Check vehicle applicability

A listed vehicle is a research lead. Confirm the engine, production range and software in the manufacturer's information.

MakeModelModel year
JaguarF-PACE2018
JaguarF-PACE2017
JaguarF-TYPE2018
JaguarF-TYPE2017
JaguarF-TYPE2016
JaguarF-TYPE2015
JaguarF-TYPE2014
JaguarXE2018
JaguarXE2017
JaguarXF2018
JaguarXF2017

Data coverage →