首页08-039-26 · JEEP
JEEP

08-039-26

厂商技术资料

发布日期
2026-02-04
NHTSA 接收日期
2026-02-12
NHTSA 收录编号
11028757

厂商摘要

以下为英文原文

Flash: Battery Pack Control Module (BPCM) Updates Customers must experience a Malfunction Indicator Lamp (MIL) illumination and the vehicle must SYMPTOM: exhibit/set one or more of the following Diagnostic Trouble Codes (DTCs):
• P0B28-00 - Hybrid/EV Battery “B” Voltage Unstable.
• P0BBE-00 - Hybrid/EV Battery Pack Voltage Variation.
• P0AA1-00 - Hybrid/EV Battery Positive Contactor “A” Stuck Closed.
• P0C78-00 - Hybrid/EV Battery System Precharge Time Too Long.
• P0CA6-00 - Hybrid/EV Battery Charging Current High.
• P0B24-00 - Hybrid/EV Battery "A" Voltage Unstable.
• P1C5E-00 - Hybrid/EV Battery State Of Health Failed.
• P0DAB-00 - Hybrid/EV Cell Balancing Performance.
• P0607-00 - ECU Internal Performance. Customers may also comment on the following:
• Vehicle does not start. NOTE: The no start condition is accompanied with the following DTCs: P0DAB-00, P0607-00, P0AA1-00, P0AA4-00, P0C78-00, P0CA6-00, P0B24-00 and/or P1C5E-00. P0B28-00 will result in a MIL for 49 days. After 49 days of the MIL, the vehicle will no longer be allowed to start. This bulletin involves reprogramming the BPCM with the latest available software. NOTE: Additional module flashes are required for this update to be effective, the following modules

NHTSA 厂商通报资料 ↗

原文报码

厂商原文中的含义

原文含义可能随车型和后缀变化。此处按来源展示,不代表通用诊断结论。

核对适用车辆

车型关联可作为查阅线索;具体发动机、生产范围和软件条件请核对厂商资料。

品牌车型年款
JeepWRANGLER 4XE2023

资料覆盖范围 →