BENTLEY
2066497/1
Communications du constructeur
- Date de publication
- 2022-03-23
- Reçu par la NHTSA
- 2022-04-07
- Identifiants NHTSA
- 10210138
Résumé du constructeur
Texte original en anglais
Bentayga Hybrid - Unable to charge the high voltage battery or charging starts and then stops. Customer statement: Unable to charge the high voltage battery, or charging starts and then stops. Workshop findings: The following DTCs are evident within the high voltage battery charger control module (Diagnostic address C6) - P33EC00: External plug in charge socket A electrical error - P31CB00: Immediate upload button Stuck Closed - P168F00: System malfunction And/or The following DTC is evident within hybrid battery management control module (Diagnostic address 8C) - P0E5E00: Battery charger control module processor performance. Measure: 1) Referring to Rep.Gr 93 - Carry out an Inspection and classification of the Hybrid battery unit AX1
Codes dans le document
Libellé du constructeur
Le libellé varie selon véhicule et suffixe ; ce n’est pas un diagnostic universel.
Bentley
P0E5E00Battery charger control module processor performanceBentley
P168F00System malfunction And/or The followingVérifier les véhicules concernés
Un véhicule répertorié est une piste. Vérifiez moteur, période de production et logiciel dans les informations du constructeur.
| Marque | Modèle | Année-modèle |
|---|---|---|
| Bentley | BENTAYGA HYBRID | 2022 |
| Bentley | BENTAYGA HYBRID | 2021 |
| Bentley | BENTAYGA HYBRID | 2020 |