AccueilB20-021 · ACURA
ACURA

B20-021

Communications du constructeur

Date de publication
2020-12-18
Reçu par la NHTSA
2020-12-23
Identifiants NHTSA
10184664

Résumé du constructeur

Texte original en anglais

"Service Bulletin - The motor power inverter (MPI), also known as the intelligent inverter unit (IIU), may fail over time due to a defective solder joint. This failure may result in one or more of the following DTC(s): -P1440 (MPI Module Output Circuit Malfunction) -P1437 (MPI Module Short Circuit) -P15A5 (Motor Current Sensor Circuit Malfunction) -P0A78 (MPI Module Internal Circuit Malfunction) -P0AE1 (Bypass Contractor Malfunction) -P0A3C (Motor Control Module (MCM) Overheating) -P0A3F (Motor Rotor Position Sensor Circuit Malfunction) -P0DA8 (MPI Module Voltage Malfunction) -P1634 (MPI Module Signal Circuit Malfunction) -P0AEE (MPI Internal Circuit Malfunction) -P0A27 (High Voltage Contactor Stays Activated) American Honda is extending the warranty coverage of the motor power inverter (MPI) on these vehicles to 15 years from the original date of purchase or 150,000 miles, whichever comes first."

Communications NHTSA ↗

Codes dans le document

Libellé du constructeur

Le libellé varie selon véhicule et suffixe ; ce n’est pas un diagnostic universel.

AcuraP0A3F
Motor Rotor Position Sensor Circuit Malfunction

NHTSA 10184664

Vérifier les véhicules concernés

Un véhicule répertorié est une piste. Vérifiez moteur, période de production et logiciel dans les informations du constructeur.

MarqueModèleAnnée-modèle
AcuraILX HYBRID2013

Périmètre des données →