MERCEDES-BENZ
LI47.70-N-079913
Comunicaciones del fabricante
- Fecha de publicación
- 2025-11-12
- Recibido por NHTSA
- 2025-12-03
- Números de registro NHTSA
- 11026052
Resumen del fabricante
Texto original en inglés
Vehicle not starting after DC charging Complaint Vehicle will not start after DC charging Warning in the instrument cluster related to High-voltage on board electrical system The following fault codes related to stuck contactor can be found in the High Voltage Control units : PTCU - N127 (Powertrain control unit)
• P154900 - There is a warning due to overcurrent in the charging system of the high-voltage electric circuit.
• P154A00 - There is a warning due to a detected crash event at standstill.
• P154B00 - There is a warning due to a stuck contactor. DCB223 - N116/5 (Direct current charge connection unit)
• P0E8929 - The input current of the on-board DC charging connection unit is too high. There is an invalid signal.
• P2BC500 - The contact ''Positive terminal'' of the contactor in the on-board DC current charge-connection unit is jammed closed
• P2BCC00 - The contact ''Negative terminal'' of the contactor in the on-board DC current charge-connection unit is jammed closed. Remedy
• Check for a new software availability for DCCU (N24/6 - Direct Current Charge connection Unit). If a new software is available, update the software first.
• Reset contactor fault through special procedure without password. ( N24/6 >> Special Procedure >> Resetting of contactor fault.)
• P154900 - There is a warning due to overcurrent in the charging system of the high-voltage electric circuit.
• P154A00 - There is a warning due to a detected crash event at standstill.
• P154B00 - There is a warning due to a stuck contactor. DCB223 - N116/5 (Direct current charge connection unit)
• P0E8929 - The input current of the on-board DC charging connection unit is too high. There is an invalid signal.
• P2BC500 - The contact ''Positive terminal'' of the contactor in the on-board DC current charge-connection unit is jammed closed
• P2BCC00 - The contact ''Negative terminal'' of the contactor in the on-board DC current charge-connection unit is jammed closed. Remedy
• Check for a new software availability for DCCU (N24/6 - Direct Current Charge connection Unit). If a new software is available, update the software first.
• Reset contactor fault through special procedure without password. ( N24/6 >> Special Procedure >> Resetting of contactor fault.)
Códigos en el documento
Descripción del fabricante
El texto puede variar por vehículo y sufijo; no es un diagnóstico universal.
Mercedes-Benz
P154900There is a warning due to overcurrent in the charging system of the high-voltage electric circuitComprueba la compatibilidad
La relación con un vehículo es una pista. Confirma motor, producción y software en la documentación del fabricante.