AUDI
A461478 2036688-
Comunicaciones del fabricante
- Fecha de publicación
- 2014-04-03
- Recibido por NHTSA
- 2017-11-08
- Números de registro NHTSA
- 10122339
Resumen del fabricante
Texto original en inglés
Customer may report that the vehicle does not start due to a discharged battery. DTC U101100 (supply voltage too low) is stored in the gateway, J533 (address word 19), and/or the electronic parking brake (EPB) control module. According to the test plan "19-Read Data Bus Keep-Awake Manager", the EPB control module kept the data bus active for prolonged periods of time. The EPB switch appears to be permanently operating (applying or releasing the parking brake) due to an internal mechanical issue or because it is jammed or blocked by debris or by a foreign object.
Códigos en el documento
Descripción del fabricante
El texto puede variar por vehículo y sufijo; no es un diagnóstico universal.
Audi
U101100supply voltage too lowComprueba la compatibilidad
La relación con un vehículo es una pista. Confirma motor, producción y software en la documentación del fabricante.