FIAT
08-048-16
Comunicaciones del fabricante
- Fecha de publicación
- 2016-04-22
- Recibido por NHTSA
- 2016-07-07
- Números de registro NHTSA
- 10076284
Resumen del fabricante
Texto original en inglés
SUBJECT: FLASH: Electric Vehicle Control Unit (EVCU) System Enhancements OVERVIEW: This bulletin involves updating the software in the EVCU. SYMPTOM/CONDITION: A small number of customers may experience a Malfunction Indicator Lamp (MIL) illumination. Upon further investigation, the technician may find the following Diagnostic Trouble Code (DTC) set in the EVCU memory: · P1A21-00 - HV Battery Contactor Control Sequence Incorrect. In addition the customer may notice one of the following conditions: · When an Electric Vehicle Supply Equipment (EVSE) is plugged in approximately 17 seconds after key off, the vehicle will not charge and will not power down. This could lead to potential 12V battery drain after prolonged period of time. · When the battery temperature is below -30°C (-22°F) and above 50°C (122°F), the thermal system does not function. · When a Level 1 EVSE is plugged in, the displayed charge time estimation for Level 2 is over estimated. The following improvements/enhancements are also included in this software release: · Improved shift strategy involving shift lever position.
Códigos en el documento
Descripción del fabricante
El texto puede variar por vehículo y sufijo; no es un diagnóstico universal.
Fiat
P1A21-00HV Battery Contactor Control Sequence IncorrectComprueba la compatibilidad
La relación con un vehículo es una pista. Confirma motor, producción y software en la documentación del fabricante.