RAM
1802522REVB
Manufacturer communications
- Publication date
- 2022-08-03
- Received by NHTSA
- 2022-10-31
- NHTSA record numbers
- 10225249 · 10225386 · 10229534
Multiple filings of the same bulletin are grouped here; original record numbers remain available.
Manufacturer summary
Original wording in English
Flash: Powertrain Control Module (PCM) Updates This bulletin involves reprogramming the PCM with the latest available software. Customers may experience a Malfunction Indicator Lamp (MIL) illumination. Upon further investigation, a technician may find that one or more of the following Diagnostic Trouble Codes (DTCs) have been set: P0325 - Knock Sensor 1 Circuit. P0601 - Internal Memory Checksum Invalid. B1040-64 - Operational Mode Status Info 1 - Signal Plausibility Failure. Customers may experience one or more of the following:Adaptive cruise is inoperative. Remote start is inoperative.
Reported code forms
Manufacturer wording
Source wording can vary by vehicle and suffix. It is shown as written, not as a universal diagnosis.
Ram
B1040-64Operational Mode Status Info 1 - Signal Plausibility FailureRam
P0325Knock Sensor 1 CircuitCheck vehicle applicability
A listed vehicle is a research lead. Confirm the engine, production range and software in the manufacturer's information.
| Make | Model | Model year |
|---|---|---|
| Ram | PROMASTER | 2022 |