RAM
08-017-20
Manufacturer communications
- Publication date
- 2020-02-06
- Received by NHTSA
- 2020-04-06
- NHTSA record numbers
- 10173352
Manufacturer summary
Original wording in English
Flash: Hybrid Control Processor (HCP) Updates This bulletin involves updating the HCP with the latest available software. Customers may experience a Malfunction Indicator Lamp (MIL) illumination. Upon further investigation the technician may find one or more of the following Diagnostic trouble Codes (DTCs) have been set:P0731-00 - Gear 1 Shift Incorrect Ratio. P0733-00 - Gear 3 Shift Incorrect Ratio (while operating in 4-Lo range). P0734-00 - Gear 4 Shift Incorrect Ratio. The customer may describe the following:Bump/clunk felt during 1-2, 2-3, 4-5 or 5-6 upshifts. Bump during coast down with medium to heavy acceleration. The following enhancement is also included in this software update:Improvements in prematurely setting the following DTCs: P0731, P0733, P0734. Improvements for the regen blending driveability. Improved 1-2, 2-3, 4-5 or 5-6 upshifts to eliminate bump/clunk felt during these upshifts.
Reported code forms
Manufacturer wording
Source wording can vary by vehicle and suffix. It is shown as written, not as a universal diagnosis.
Ram
P0731-00Gear 1 Shift Incorrect RatioRam
P0733-00Gear 3 Shift Incorrect Ratio (while operating in 4-Lo range)Ram
P0734-00Gear 4 Shift Incorrect RatioCheck vehicle applicability
A listed vehicle is a research lead. Confirm the engine, production range and software in the manufacturer's information.
| Make | Model | Model year |
|---|---|---|
| Ram | 1500 | 2020 |