原廠摘要
以下為英文原文
Bentayga Hybrid - Unable to charge the high voltage battery or charging starts and then stops. Customer statement: Unable to charge the high voltage battery, or charging starts and then stops. Workshop findings: The following DTCs are evident within the high voltage battery charger control module (Diagnostic address C6) - P33EC00: External plug in charge socket A electrical error - P31CB00: Immediate upload button Stuck Closed - P168F00: System malfunction And/or The following DTC is evident within hybrid battery management control module (Diagnostic address 8C) - P0E5E00: Battery charger control module processor performance. Measure: 1) Referring to Rep.Gr 93 - Carry out an Inspection and classification of the Hybrid battery unit AX1
原文故障碼
原廠原文中的含義
原文含義可能隨車型與後綴變化。此處依來源顯示,不代表通用診斷結論。
Bentley
P0E5E00Battery charger control module processor performanceBentley
P168F00System malfunction And/or The following核對適用車輛
車型關聯可作查閱線索;引擎、生產範圍與軟體條件請核對原廠資料。
| 品牌 | 車型 | 年式 |
|---|---|---|
| Bentley | BENTAYGA HYBRID | 2022 |
| Bentley | BENTAYGA HYBRID | 2021 |
| Bentley | BENTAYGA HYBRID | 2020 |