AUDI
A461472 2034404-
原廠技術資料
- 發布日期
- 2014-03-07
- NHTSA 接收日期
- 2017-11-08
- NHTSA 收錄編號
- 10122288
原廠摘要
以下為英文原文
Supersedes Technical Service Bulletin Group 46 number 13-48 dated July 18, 2013. Customer may report that the vehicle does not start due to a discharged battery. DTC U101100 (supply voltage too low) is stored in the gateway, J533 (address word 19), and/or the electronic parking brake (EPB) control module, J540 (address word 53). According to the test plan "19-Read Data Bus Keep-Awake Manager", the EPB control module kept the data bus active for prolonged periods of time. The EPB switch appears to be permanently operating (applying or releasing the parking brake) due to an internal mechanical issue or because it is jammed or blocked by debris or by a foreign object. Test plan "19-Read Data Bus Keep-Awake Manager" identifies the EPB control module as keeping the data bus active for prolonged periods of time.
原文故障碼
原廠原文中的含義
原文含義可能隨車型與後綴變化。此處依來源顯示,不代表通用診斷結論。
Audi
U101100supply voltage too low核對適用車輛
車型關聯可作查閱線索;引擎、生產範圍與軟體條件請核對原廠資料。
| 品牌 | 車型 | 年式 |
|---|---|---|
| Audi | A4 ALLROAD | 2013 |
| Audi | A5 | 2013 |
| Audi | Q5 | 2013 |