MERCEDES-BENZ
LI47-70-N-080294
厂商技术资料
- 发布日期
- 2026-03-03
- NHTSA 接收日期
- 2026-04-02
- NHTSA 收录编号
- 11030621
厂商摘要
以下为英文原文
eSprinter model series 907: Intermittent no-start condition Complaint Intermittent no-start condition; partial restart without "Ready" status in display. Concern may be rectified after bus idle and/or circuit 30 deep reset. Cause As a result of inaccuracies in Battery Management System measurements, the BMS may record the following fault codes: P0ABD00 - Battery voltage sensor A in the hybrid/high-voltage battery module has a short circuit to positive. P0B171C - Battery voltage sensor B in the hybrid/high-voltage battery module has a short circuit to positive. The vol-tage value is outside the permissible range P181D12 - The reference voltage at output A has exceeded the limit value. There is a short circuit to positive Remedy Perform a software update of control unit G1/9 - battery management system (BMS) (BMS907)
原文报码
厂商原文中的含义
原文含义可能随车型和后缀变化。此处按来源展示,不代表通用诊断结论。
Mercedes-Benz
P0ABD00Battery voltage sensor A in the hybrid/high-voltage battery module has a short circuit to positiveMercedes-Benz
P0B171CBattery voltage sensor B in the hybrid/high-voltage battery module has a short circuit to positive核对适用车辆
车型关联可作为查阅线索;具体发动机、生产范围和软件条件请核对厂商资料。