HONDA
A20-030
厂商技术资料
- 发布日期
- 2020-12-18
- NHTSA 接收日期
- 2020-12-23
- NHTSA 收录编号
- 10184658
厂商摘要
以下为英文原文
"Service Bulletin - The Motor Power Inverter (MPI), also known as the Intelligent Inverter Unit (IIU), may fail over time due to a defective solder joint. This failure may result in one or more of the following DTC(s): -P1440 (MPI Module Output Circuit Malfunction) -P1437 (MPI Module Short Circuit) -P15A5 (Motor Current Sensor Circuit Malfunction) -P0A78 (MPI Module Internal Circuit Malfunction) -P0AE1 (Bypass Contractor Malfunction) -P0A3C (Motor Control Module (MCM) Overheating) -P0A3F (Motor Rotor Position Sensor Circuit Malfunction) -P0DA8 (MPI Module Voltage Malfunction) -P1634 (MPI Module Signal Circuit Malfunction) -P0AEE (MPI Internal Circuit Malfunction) -P0A27 (High Voltage Contactor Stays Activated) American Honda is extending the warranty coverage of the motor power inverter (MPI) on these vehicles to 15 years from the original date of purchase or 150,000 miles, whichever comes first."
原文报码
厂商原文中的含义
原文含义可能随车型和后缀变化。此处按来源展示,不代表通用诊断结论。
Honda
P0A27High Voltage Contactor Stays ActivatedHonda
P0A3FMotor Rotor Position Sensor Circuit MalfunctionHonda
P0A78MPI Module Internal Circuit MalfunctionHonda
P0AEEMPI Internal Circuit MalfunctionHonda
P0DA8MPI Module Voltage MalfunctionHonda
P1437MPI Module Short CircuitHonda
P1440MPI Module Output Circuit MalfunctionHonda
P15A5Motor Current Sensor Circuit MalfunctionHonda
P1634MPI Module Signal Circuit Malfunction核对适用车辆
车型关联可作为查阅线索;具体发动机、生产范围和软件条件请核对厂商资料。
| 品牌 | 车型 | 年款 |
|---|---|---|
| Honda | CIVIC HYBRID | 2015 |
| Honda | CIVIC HYBRID | 2014 |
| Honda | CIVIC HYBRID | 2013 |
| Honda | CIVIC HYBRID | 2012 |