eSprinter model series 907: Intermittent no-start condition Complaint Intermittent no-start condition; partial restart without "Ready" status in display. Concern may be rectified after bus idle and/or circuit 30 deep reset. Cause As a result of inaccuracies in Battery Management System measurements, the BMS may record the following fault codes: P0ABD00 - Battery voltage sensor A in the hybrid/high-voltage battery module has a short circuit to positive. P0B171C - Battery voltage sensor B in the hybrid/high-voltage battery module has a short circuit to positive. The vol-tage value is outside the permissible range P181D12 - The reference voltage at output A has exceeded the limit value. There is a short circuit to positive Remedy Perform a software update of control unit G1/9 - battery management system (BMS) (BMS907)

Материалы NHTSA ↗

Коды в оригинале

Формулировка производителя

Формулировки зависят от машины и суффикса, это не универсальный диагноз.

Mercedes-BenzP0ABD00
Battery voltage sensor A in the hybrid/high-voltage battery module has a short circuit to positive

NHTSA 11030621

Mercedes-BenzP0B171C
Battery voltage sensor B in the hybrid/high-voltage battery module has a short circuit to positive

NHTSA 11030621

Проверьте применимость

Связь с автомобилем — отправная точка. Уточняйте двигатель, период выпуска и ПО по данным производителя.

МаркаМодельМодельный год
Mercedes-BenzESPRINTER2025
Mercedes-BenzESPRINTER2024

Охват данных →