KIA
TSB_ELE192_R1
Материалы производителя
- Дата публикации
- 2023-01-18
- Получено NHTSA
- 2023-02-02
- Номера записей NHTSA
- 10230492
Аннотация производителя
Оригинал на английском
TECHNICAL SERVICE BULLETIN: SERVICE ACTION: BMS/OPU/MCU LOGIC IMPROVEMENT (SA411) - This bulletin has been revised to include additional information. New/revised sections of this bulletin are indicated by a black bar in the margin area. This bulletin provides the procedure to improve the logic of the Battery Management System (BMS), Oil Pump Control Unit (OPU) and Motor Control Unit (MCU) on some 2017-2019MY Optima (JF P/HEV) vehicles, produced from August 25, 2016 through September 13, 2018 (refer to page 8) in order to improve the BMS diagnosis logic, OPU judgment logic for DTC P1B77 (High Voltage Battery Pre-Charging fault) and MCU communication logic.
Коды в оригинале
Формулировка производителя
Формулировки зависят от машины и суффикса, это не универсальный диагноз.
Kia
P1B77High Voltage Battery Pre-Charging faultПроверьте применимость
Связь с автомобилем — отправная точка. Уточняйте двигатель, период выпуска и ПО по данным производителя.
| Марка | Модель | Модельный год |
|---|---|---|
| Kia | OPTIMA | 2019 |
| Kia | OPTIMA | 2018 |
| Kia | OPTIMA | 2017 |
| Kia | OPTIMA HYBRID | 2019 |
| Kia | OPTIMA HYBRID | 2018 |
| Kia | OPTIMA HYBRID | 2017 |
| Kia | OPTIMA PHEV | 2019 |
| Kia | OPTIMA PHEV | 2018 |
| Kia | OPTIMA PHEV | 2017 |