FIAT
08-048-16
Материалы производителя
- Дата публикации
- 2016-04-22
- Получено NHTSA
- 2018-06-11
- Номера записей NHTSA
- 10139961
Аннотация производителя
Оригинал на английском
FLASH: Electric Vehicle Control Unit (EVCU) System Enhancements This bulletin involves updating the software in the EVCU. A small number of customers may experience a Malfunction Indicator Lamp (MIL) illumination. Upon further investigation, the technician may find the following Diagnostic Trouble Code (DTC) set in the EVCU memory: · P1A21-00 - HV Battery Contactor Control Sequence Incorrect. In addition the customer may notice one of the following conditions: · When an Electric Vehicle Supply Equipment (EVSE) is plugged in approximately 17 seconds after key off, the vehicle will not charge and will not power down. This could lead to potential 12V battery drain after prolonged period of time. · When the battery temperature is below -30°C (-22°F) and above 50°C (122°F), the thermal system does not function. · When a Level 1 EVSE is plugged in, the displayed charge time estimation for Level 2 is over estimated. The following improvements/enhancements are also included in this software release: · Improved shift strategy involving shift lever position.
Коды в оригинале
Формулировка производителя
Формулировки зависят от машины и суффикса, это не универсальный диагноз.
Fiat
P1A21-00HV Battery Contactor Control Sequence IncorrectПроверьте применимость
Связь с автомобилем — отправная точка. Уточняйте двигатель, период выпуска и ПО по данным производителя.