InícioA20-030 · HONDA
HONDA

A20-030

Comunicados do fabricante

Data de publicação
2020-12-18
Recebido pela NHTSA
2020-12-23
Números de registro NHTSA
10184658

Resumo do fabricante

Texto original em inglês

"Service Bulletin - The Motor Power Inverter (MPI), also known as the Intelligent Inverter Unit (IIU), may fail over time due to a defective solder joint. This failure may result in one or more of the following DTC(s): -P1440 (MPI Module Output Circuit Malfunction) -P1437 (MPI Module Short Circuit) -P15A5 (Motor Current Sensor Circuit Malfunction) -P0A78 (MPI Module Internal Circuit Malfunction) -P0AE1 (Bypass Contractor Malfunction) -P0A3C (Motor Control Module (MCM) Overheating) -P0A3F (Motor Rotor Position Sensor Circuit Malfunction) -P0DA8 (MPI Module Voltage Malfunction) -P1634 (MPI Module Signal Circuit Malfunction) -P0AEE (MPI Internal Circuit Malfunction) -P0A27 (High Voltage Contactor Stays Activated) American Honda is extending the warranty coverage of the motor power inverter (MPI) on these vehicles to 15 years from the original date of purchase or 150,000 miles, whichever comes first."

Comunicados da NHTSA ↗

Códigos no documento

Descrição do fabricante

O texto varia por veículo e sufixo; não é diagnóstico universal.

HondaP0A3F
Motor Rotor Position Sensor Circuit Malfunction

NHTSA 10184658

Confira a aplicação ao veículo

A relação com um veículo é uma pista. Confirme motor, produção e software na documentação do fabricante.

MarcaModeloAno-modelo
HondaCIVIC HYBRID2015
HondaCIVIC HYBRID2014
HondaCIVIC HYBRID2013
HondaCIVIC HYBRID2012