제조사 요약
영어 원문
Motor Generator Unit (MGU) Connector Not Fully Seated This bulletin involves replacing the MGU. Customers may experience a Malfunction Indicator Lamp (MIL) illumination. Upon further investigation the technician may find one or more ofthe following Diagnostic Trouble Codes (DTCs). U0594 - Implausible Data Received From HCP. P1B03-00 - Resolver Signal / MCPA Rationality. P0A3F-00 - Drive Motor A Position Sensor 1 Circuit. P0607-00 - ECU Internal Performance. P1C64-00 - Hybrid Perf - Engine Speed Below Target During Autostart. P0A92-00 - Hybrid Generator Performance. Customers may also experience the following: The vehicle has 15-40 minutes of driving time before a vehicle stall.The vehicle will be unable to re-start. The vehicle will lose charging of the main 12V battery. A check engine light and/or a low battery light illuminates.
원문 코드 표기
제조사 자료의 표현
차량과 접미 문자에 따라 다를 수 있습니다. 원문 표현이며 공통 진단이 아닙니다.
Ram
P0607-00ECU Internal PerformanceRam
P0A3F-00Drive Motor A Position Sensor 1 CircuitRam
P0A92-00Hybrid Generator PerformanceRam
P1B03-00Resolver Signal / MCPA RationalityRam
P1C64-00Hybrid Perf - Engine Speed Below Target During Autostart적용 차량 확인