FIAT
08-048-16
メーカー技術情報
- 発行日
- 2016-04-22
- NHTSA 受理日
- 2016-07-07
- NHTSA 記録番号
- 10076284
メーカー概要
英語の原文
SUBJECT: FLASH: Electric Vehicle Control Unit (EVCU) System Enhancements OVERVIEW: This bulletin involves updating the software in the EVCU. SYMPTOM/CONDITION: A small number of customers may experience a Malfunction Indicator Lamp (MIL) illumination. Upon further investigation, the technician may find the following Diagnostic Trouble Code (DTC) set in the EVCU memory: · P1A21-00 - HV Battery Contactor Control Sequence Incorrect. In addition the customer may notice one of the following conditions: · When an Electric Vehicle Supply Equipment (EVSE) is plugged in approximately 17 seconds after key off, the vehicle will not charge and will not power down. This could lead to potential 12V battery drain after prolonged period of time. · When the battery temperature is below -30°C (-22°F) and above 50°C (122°F), the thermal system does not function. · When a Level 1 EVSE is plugged in, the displayed charge time estimation for Level 2 is over estimated. The following improvements/enhancements are also included in this software release: · Improved shift strategy involving shift lever position.
原文のコード表記
メーカー資料の表記
意味は車種や後続文字で変わることがあります。原文の記載であり共通診断ではありません。
Fiat
P1A21-00HV Battery Contactor Control Sequence Incorrect対象車両を確認
掲載車両は調査の手がかりです。エンジン、製造期間、ソフトウェア条件はメーカー資料で確認してください。