होमLI47-70-N-080294 · MERCEDES-BENZ
MERCEDES-BENZ

LI47-70-N-080294

निर्माता की तकनीकी जानकारी

प्रकाशन तारीख
2026-03-03
NHTSA प्राप्ति तारीख
2026-04-02
NHTSA रिकॉर्ड नंबर
11030621

निर्माता सारांश

मूल अंग्रेज़ी विवरण

eSprinter model series 907: Intermittent no-start condition Complaint Intermittent no-start condition; partial restart without "Ready" status in display. Concern may be rectified after bus idle and/or circuit 30 deep reset. Cause As a result of inaccuracies in Battery Management System measurements, the BMS may record the following fault codes: P0ABD00 - Battery voltage sensor A in the hybrid/high-voltage battery module has a short circuit to positive. P0B171C - Battery voltage sensor B in the hybrid/high-voltage battery module has a short circuit to positive. The vol-tage value is outside the permissible range P181D12 - The reference voltage at output A has exceeded the limit value. There is a short circuit to positive Remedy Perform a software update of control unit G1/9 - battery management system (BMS) (BMS907)

NHTSA निर्माता जानकारी ↗

मूल कोड रूप

निर्माता का मूल विवरण

विवरण वाहन और प्रत्यय से बदल सकता है; यह सार्वभौमिक निदान नहीं है।

Mercedes-BenzP0ABD00
Battery voltage sensor A in the hybrid/high-voltage battery module has a short circuit to positive

NHTSA 11030621

Mercedes-BenzP0B171C
Battery voltage sensor B in the hybrid/high-voltage battery module has a short circuit to positive

NHTSA 11030621

वाहन पर लागू होने की जाँच

सूची में वाहन का होना जाँच की शुरुआत है। निर्माता की जानकारी में इंजन, उत्पादन अवधि और सॉफ़्टवेयर जाँचें।

निर्मातामॉडलमॉडल वर्ष
Mercedes-BenzESPRINTER2025
Mercedes-BenzESPRINTER2024

डेटा कवरेज →