InicioLI47.70-P-076030 · MERCEDES-BENZ
MERCEDES-BENZ

LI47.70-P-076030

Comunicaciones del fabricante

Fecha de publicación
2026-02-24
Recibido por NHTSA
2026-02-27
Números de registro NHTSA
11029061

Resumen del fabricante

Texto original en inglés

Complaint After the charging process is complete, an instrument cluster message with a charging error appears and FC P0CFE00 is stored in control unit "N83 - AC charger for high-voltage battery (SG-LG)". The fault message and the fault memory entry can also appear at the beginning of the charging pause during delayed charging. Both only occur in combination with active pre-entry climate control. Cause Software in control unit "N83 - AC charger for high-voltage battery (SG-LG)". Remedy For plug-in Model Series167, 206, 214, 223, 247, 254: Carry out software update and SCN coding for the control unit "N83 – AC charger for high-voltage battery (SG-LG)". For model series 243: Carry out software update and SCN coding for the control units "N116/5 – DC charge-connection unit (DCCU)" and "N83/11 – AC charger for high-voltage battery (SG-LG)"

Comunicaciones de NHTSA ↗

Códigos en el documento

Comprueba la compatibilidad

La relación con un vehículo es una pista. Confirma motor, producción y software en la documentación del fabricante.

MarcaModeloAño del modelo
Mercedes-BenzGLB 2502025
Mercedes-BenzGLB 2502024
Mercedes-BenzGLB 2502023
Mercedes-BenzGLB 2502022
Mercedes-BenzGLB 2502021
Mercedes-BenzGLB 2502020
Mercedes-BenzGLB 250 4MATIC2026
Mercedes-BenzGLB 250 4MATIC2021
Mercedes-BenzGLB 250 4MATIC2020
Mercedes-BenzGLC 300E2025
Mercedes-BenzGLC 350 E 4MATIC2026
Mercedes-BenzGLC 350 E 4MATIC2025
Mercedes-BenzGLE 350 E2022
Mercedes-BenzGLE 350 E2021
Mercedes-BenzGLE 350 E2020
Mercedes-BenzGLE 450E 4MATIC2025
Mercedes-BenzGLE 450E 4MATIC2024
Mercedes-BenzS 580 E2023
Mercedes-BenzS 580 E 4MATIC2025
Mercedes-BenzS 580 E 4MATIC2024
Mercedes-BenzS 580 E 4MATIC2023

Cobertura de datos →