StartseiteLI47-70-N-080294 · MERCEDES-BENZ
MERCEDES-BENZ

LI47-70-N-080294

Herstellerinformationen

Veröffentlichung
2026-03-03
Bei NHTSA eingegangen
2026-04-02
NHTSA-Datensatznummern
11030621

Herstellerzusammenfassung

Englischer Originaltext

eSprinter model series 907: Intermittent no-start condition Complaint Intermittent no-start condition; partial restart without "Ready" status in display. Concern may be rectified after bus idle and/or circuit 30 deep reset. Cause As a result of inaccuracies in Battery Management System measurements, the BMS may record the following fault codes: P0ABD00 - Battery voltage sensor A in the hybrid/high-voltage battery module has a short circuit to positive. P0B171C - Battery voltage sensor B in the hybrid/high-voltage battery module has a short circuit to positive. The vol-tage value is outside the permissible range P181D12 - The reference voltage at output A has exceeded the limit value. There is a short circuit to positive Remedy Perform a software update of control unit G1/9 - battery management system (BMS) (BMS907)

NHTSA-Herstellerinformationen ↗

Codes im Original

Wortlaut des Herstellers

Wortlaut kann nach Fahrzeug und Suffix variieren; keine universelle Diagnose.

Mercedes-BenzP0ABD00
Battery voltage sensor A in the hybrid/high-voltage battery module has a short circuit to positive

NHTSA 11030621

Mercedes-BenzP0B171C
Battery voltage sensor B in the hybrid/high-voltage battery module has a short circuit to positive

NHTSA 11030621

Fahrzeugzuordnung prüfen

Eine Fahrzeugzuordnung ist ein Recherchehinweis. Motor, Produktionszeitraum und Software anhand der Herstellerangaben prüfen.

MarkeModellModelljahr
Mercedes-BenzESPRINTER2025
Mercedes-BenzESPRINTER2024

Datenabdeckung →