StartseiteB20-021 · ACURA
ACURA

B20-021

Herstellerinformationen

Veröffentlichung
2020-12-18
Bei NHTSA eingegangen
2020-12-23
NHTSA-Datensatznummern
10184664

Herstellerzusammenfassung

Englischer Originaltext

"Service Bulletin - The motor power inverter (MPI), also known as the intelligent inverter unit (IIU), may fail over time due to a defective solder joint. This failure may result in one or more of the following DTC(s): -P1440 (MPI Module Output Circuit Malfunction) -P1437 (MPI Module Short Circuit) -P15A5 (Motor Current Sensor Circuit Malfunction) -P0A78 (MPI Module Internal Circuit Malfunction) -P0AE1 (Bypass Contractor Malfunction) -P0A3C (Motor Control Module (MCM) Overheating) -P0A3F (Motor Rotor Position Sensor Circuit Malfunction) -P0DA8 (MPI Module Voltage Malfunction) -P1634 (MPI Module Signal Circuit Malfunction) -P0AEE (MPI Internal Circuit Malfunction) -P0A27 (High Voltage Contactor Stays Activated) American Honda is extending the warranty coverage of the motor power inverter (MPI) on these vehicles to 15 years from the original date of purchase or 150,000 miles, whichever comes first."

NHTSA-Herstellerinformationen ↗

Codes im Original

Wortlaut des Herstellers

Wortlaut kann nach Fahrzeug und Suffix variieren; keine universelle Diagnose.

AcuraP0A3F
Motor Rotor Position Sensor Circuit Malfunction

NHTSA 10184664

Fahrzeugzuordnung prüfen

Eine Fahrzeugzuordnung ist ein Recherchehinweis. Motor, Produktionszeitraum und Software anhand der Herstellerangaben prüfen.

MarkeModellModelljahr
AcuraILX HYBRID2013

Datenabdeckung →