Original wording in English

Complaint After the charging process is complete, an instrument cluster message with a charging error appears and FC P0CFE00 is stored in control unit "N83 - AC charger for high-voltage battery (SG-LG)". The fault message and the fault memory entry can also appear at the beginning of the charging pause during delayed charging. Both only occur in combination with active pre-entry climate control. Cause Software in control unit "N83 - AC charger for high-voltage battery (SG-LG)". Remedy For plug-in Model Series167, 206, 214, 223, 247, 254: Carry out software update and SCN coding for the control unit "N83 – AC charger for high-voltage battery (SG-LG)". For model series 243: Carry out software update and SCN coding for the control units "N116/5 – DC charge-connection unit (DCCU)" and "N83/11 – AC charger for high-voltage battery (SG-LG)"

NHTSA manufacturer communications ↗

Reported code forms

Check vehicle applicability

A listed vehicle is a research lead. Confirm the engine, production range and software in the manufacturer's information.

MakeModelModel year
Mercedes-BenzGLB 2502025
Mercedes-BenzGLB 2502024
Mercedes-BenzGLB 2502023
Mercedes-BenzGLB 2502022
Mercedes-BenzGLB 2502021
Mercedes-BenzGLB 2502020
Mercedes-BenzGLB 250 4MATIC2026
Mercedes-BenzGLB 250 4MATIC2021
Mercedes-BenzGLB 250 4MATIC2020
Mercedes-BenzGLC 300E2025
Mercedes-BenzGLC 350 E 4MATIC2026
Mercedes-BenzGLC 350 E 4MATIC2025
Mercedes-BenzGLE 350 E2022
Mercedes-BenzGLE 350 E2021
Mercedes-BenzGLE 350 E2020
Mercedes-BenzGLE 450E 4MATIC2025
Mercedes-BenzGLE 450E 4MATIC2024
Mercedes-BenzS 580 E2023
Mercedes-BenzS 580 E 4MATIC2025
Mercedes-BenzS 580 E 4MATIC2024
Mercedes-BenzS 580 E 4MATIC2023

Data coverage →