MERCEDES-BENZ
LI54.10-P-079340
Manufacturer communications
- Publication date
- 2025-05-27
- Received by NHTSA
- 2025-05-28
- NHTSA record numbers
- 11018611
Manufacturer summary
Original wording in English
Complaint Vehicle will not start after charging, HV warning in IC Cause Due to charging error from the charging EVSE the contactors for the DCCU are jammed closed and must be reset via Xentry. Short test found fault code P154B00 in PTCU warning for stuck contactor. Remedy Check for new DCCU (N116/5) SW. Perform SW update to DCCU (N116/5) via XENTRY. Reset contactors through special procedures through N116/5. If no new SW is available - Open TIPS case. Please provide HV CUL and QT in TIPS case.
Reported code forms
Check vehicle applicability
A listed vehicle is a research lead. Confirm the engine, production range and software in the manufacturer's information.
| Make | Model | Model year |
|---|---|---|
| Mercedes-Benz | EQB 250+ | 2025 |
| Mercedes-Benz | EQB 250+ | 2024 |
| Mercedes-Benz | EQB 250+ | 2023 |
| Mercedes-Benz | EQB 300 4MATIC | 2025 |
| Mercedes-Benz | EQB 300 4MATIC | 2024 |
| Mercedes-Benz | EQB 300 4MATIC | 2023 |
| Mercedes-Benz | EQB 300 4MATIC | 2022 |
| Mercedes-Benz | EQB 350 4MATIC | 2025 |
| Mercedes-Benz | EQB 350 4MATIC | 2024 |
| Mercedes-Benz | EQB 350 4MATIC | 2023 |
| Mercedes-Benz | EQB 350 4MATIC | 2022 |