原廠摘要

以下為英文原文

Some 2020-2022 Aviator/Explorer Hybrid vehicles may experience a low battery warning message displayed in the message center with diagnostic trouble code B11D9 present in the body control module (BCM). Refer to Workshop Manual, Section 414-01, Pinpoint Test C for diagnosis and repair. If the 125 amp fuse on the 14300 wire harness at the auxiliary battery is open, it is not necessary to replace a complete wire harness to obtain this fuse. Service part number JU5Z-14526-A is now available separately for service.