首頁2066502/1 · BENTLEY
BENTLEY

2066502/1

原廠技術資料

發布日期
2022-03-23
NHTSA 接收日期
2022-04-07
NHTSA 收錄編號
10210076

原廠摘要

以下為英文原文

Charging starts and stops when using a public charging unit. Customer statement / workshop findings: When using a public charging unit to charge the high voltage battery, charging starts and is then interrupted/stops Workshop findings The following DTC is also evident: P33E800: Charge socket A, charge connector lock mechanical malfunction passive/sporadic. Measure: 1) Referring to Rep.Gr 93 - Carry out an Inspection and classification of the Hybrid battery unit AX1 VERY IMPORTANT: In the event that the classification result of the battery is Normal the operative should conduct the remaining steps of this TPI from step 2 However If the classification result of the battery is either Danger or Warning then move the car to the quarantine area and raise a DISS immediately, the operative MUST NOT continue with any other work unless instructed via the open DISS query 2) Check the operation of the charging system using the customers and the retailers own charging equipment 3) Run a full diagnostic log and check if the DTC within the Technical background section are evident.

NHTSA 原廠通報資料 ↗

原文故障碼

核對適用車輛

車型關聯可作查閱線索;引擎、生產範圍與軟體條件請核對原廠資料。

品牌車型年式
BentleyBENTAYGA HYBRID2022
BentleyBENTAYGA HYBRID2021
BentleyBENTAYGA HYBRID2020
BentleyFLYING SPUR2022

資料涵蓋範圍 →