TOYOTA
T-SB-0023-20
原廠技術資料
- 發布日期
- 2020-03-10
- NHTSA 接收日期
- 2020-04-13
- NHTSA 收錄編號
- 10173802
原廠摘要
以下為英文原文
TSB: Some 2019 ? 2020 model year Avalon Hybrid, Camry Hybrid, and RAV4 Hybrid vehicles may exhibit a MIL ON condition with a ?Hybrid System Malfunction? message displayed and one or more of the following DTC(s) that represent an over current between the MG1, MG2, and inverter/PCU: ?P1C5D19 ? Drive Motor "A" Inverter Circuit Current Above Threshold ?P1C5F19 ? Generator Inverter Circuit Current Above Threshold These conditions typically occur on low vehicle mileage (less than 5,000). After an occurrence, the vehicle will be able to run normally with no drivability issues. Follow the Repair Procedure in this bulletin to address these conditions
原文故障碼
核對適用車輛
車型關聯可作查閱線索;引擎、生產範圍與軟體條件請核對原廠資料。
| 品牌 | 車型 | 年式 |
|---|---|---|
| Toyota | AVALON HYBRID | 2020 |
| Toyota | AVALON HYBRID | 2019 |
| Toyota | CAMRY HYBRID | 2020 |
| Toyota | CAMRY HYBRID | 2019 |
| Toyota | RAV4 HYBRID | 2020 |
| Toyota | RAV4 HYBRID | 2019 |