首页LI47.70-P-078563 · MERCEDES-BENZ, MERCEDES-MAYBACH
MERCEDES-BENZ, MERCEDES-MAYBACH

LI47.70-P-078563

厂商技术资料

发布日期
2024-11-04
NHTSA 接收日期
2024-11-11
NHTSA 收录编号
11010435

厂商摘要

以下为英文原文

Complaint -Check engine light(MIL) is ON. -Current and stored fault code in DCCU and PTCU : P2E9873 The position sensor of the exterior socket flap of the vehicle socket (direct current) has an electrical fault. The actuator does not open. -Starting the vehicle or Charging the vehicle is normal without any issues. Cause Software in the "N116/5 - Direct current charge connection unit (DCCU)" control unit. Remedy SW remedy for N116/5(DC-Charging control unit box) is in progress. Once the software is available, update the software for N116/5 and perform SCN coding of N116/5 For this issue, the vehicle starting or charging functions are not typically affected. Do not replace any parts. Replacing parts will not bring a solution for this issue.

NHTSA 厂商通报资料 ↗

原文报码

核对适用车辆

车型关联可作为查阅线索;具体发动机、生产范围和软件条件请核对厂商资料。

品牌车型年款
Mercedes-BenzAMG C432024
Mercedes-BenzAMG C432023
Mercedes-BenzAMG C63 S E2024
Mercedes-BenzAMG GLC432024
Mercedes-BenzAMG GLE532022
Mercedes-BenzAMG GLE532021
Mercedes-BenzAMG GLE53 4MATIC+2024
Mercedes-BenzAMG GLE53 4MATIC+2023
Mercedes-BenzAMG GLE63 S2022
Mercedes-BenzAMG GLE63 S2021
Mercedes-BenzAMG GLE63 S 4MATIC+2024
Mercedes-BenzAMG GLE63 S 4MATIC+2023
Mercedes-BenzC 3002024
Mercedes-BenzC 3002023
Mercedes-BenzC 3002022
Mercedes-BenzE 3502024
Mercedes-BenzE 4502024
Mercedes-BenzGLC 3002024
Mercedes-BenzGLC 3002023
Mercedes-BenzGLE 3502024
Mercedes-BenzGLE 3502023
Mercedes-BenzGLE 3502022
Mercedes-BenzGLE 3502021
Mercedes-BenzGLE 3502020
Mercedes-BenzGLE 4502024
Mercedes-BenzGLE 4502023
Mercedes-BenzGLE 4502022
Mercedes-BenzGLE 4502021
Mercedes-BenzGLE 4502020
Mercedes-BenzGLE 450E 4MATIC2025

资料覆盖范围 →