首页LI54.10-P-075043 · MERCEDES-BENZ, MERCEDES-MAYBACH
MERCEDES-BENZ, MERCEDES-MAYBACH

LI54.10-P-075043

厂商技术资料

发布日期
2022-07-18
NHTSA 接收日期
2022-08-04
NHTSA 收录编号
10217160

厂商摘要

以下为英文原文

Complaint On affected hybrid vehicles of model series 223, a sporadic or continuously displayed red 12V warning message is shown in the instrument cluster. Cause Based on the current status of the analyses, 2 different causes may be considered probable: ·Failure of the current limiter module: The fault does not necessarily trigger a fault code. This fault profile is likely in the event of continuous 12V red messages. ·A second cause of the fault is indicated by the saved fault codes P0E32FA in the HV DC/DC converter (N82/2; see XENTRY Diagnosis for fault code) and, in some cases, B161609 in the electronic ignition switch (N73). This fault profile is likely in the event of sporadic 12V red messages. Remedy For cause analysis, the quick test for the vehicle should be examined for the presence of either of the two fault codes specified above. If no DTCs are saved and a continuous 12V red message is shown in the instrument cluster, the current limiter module is likely faulty and the component part must be replaced. In the event that the fault codes are saved in the DC/DC converter, the guided check must be followed. Depending on the result of the diagnosis, the work must be invoiced to the SSL of the corresponding component part.

NHTSA 厂商通报资料 ↗

原文报码

核对适用车辆

车型关联可作为查阅线索;具体发动机、生产范围和软件条件请核对厂商资料。

品牌车型年款
Mercedes-BenzS 500 4MATIC2022
Mercedes-BenzS 580 4MATIC2022
Mercedes-MaybachS 580 4MATIC2022
Mercedes-MaybachS 680 4MATIC2022

资料覆盖范围 →