InícioLI54.10-P-080684 · MERCEDES-BENZ
MERCEDES-BENZ

LI54.10-P-080684

Comunicados do fabricante

Data de publicação
2026-08-06
Recebido pela NHTSA
2026-08-11
Números de registro NHTSA
11036102

Resumo do fabricante

Texto original em inglês

Complaint When disconnecting or connecting the charging connector, the charging socket flashes red and red warning messages are displayed in the instrument cluster. Immediately after that, neither driving nor charging is possible. Cause P292900: If the charging cable connector is removed approximately 5 to 7 seconds after the charging process has ended, a fault is triggered. Remedy If this fault occurs, please follow these steps: 1) Wait for bus idle -> driving should be possible again. Note: Charging is still not possible. The fault will keep recurring as long as the fault is stored in the fault memory. 2) Plug in charging cable and check if fault (P292900 or P0AE173) is active. Clear active fault. Charging should be possible after the fault has been cleared. To prevent the fault from recurring, after the charging process has ended, wait at least 15 seconds before disconnecting the AC charging cable connector. Please create a TIPS case including quick test and HV control module log.

Comunicados da NHTSA ↗

Códigos no documento

Confira a aplicação ao veículo

A relação com um veículo é uma pista. Confirme motor, produção e software na documentação do fabricante.

MarcaModeloAno-modelo
Mercedes-BenzG 580 E2026

Cobertura dos dados →