Resumo do fabricante

Texto original em inglês

Complaint Random heating of air conditioning system. Cause Temperature sensor in overhead control panel (OCP) delivering incorrect values: The temperature sensor in the overhead control panel is malfunctioning. Fault code B110709 or fault code B11F697 are present in the overhead control panel with the status (active) or (active stored). or The temperature sensor in the overhead control panel measures an incorrect temperature (the temperature value can be checked against the actual value in the overhead control panel) If the above-mentioned fault code is not present, the cause could be malfunction on the air conditioning system. Remedy If one of the above-mentioned fault codes should occur, a TIPS case must be created here. If the above fault codes or actual value differences are present in the OCP - please send the case to the Body/Chassis/ Entertainment inbox. Otherwise, the case must be sent to the HV/LV inbox for support in A/C diagnosis. *** It is not necessary to replace the overhead control panel ***

Comunicados da NHTSA ↗

Códigos no documento

Confira a aplicação ao veículo

A relação com um veículo é uma pista. Confirme motor, produção e software na documentação do fabricante.

MarcaModeloAno-modelo
Mercedes-MaybachS 580 4MATIC2023
Mercedes-MaybachS 580 4MATIC2022
Mercedes-MaybachS 6802024
Mercedes-MaybachS 6802023
Mercedes-MaybachS 680 4MATIC2023
Mercedes-MaybachS 680 4MATIC2022

Cobertura dos dados →