InícioT-SB-0023-20 · TOYOTA
TOYOTA

T-SB-0023-20

Comunicados do fabricante

Data de publicação
2020-03-10
Recebido pela NHTSA
2020-04-13
Números de registro NHTSA
10173802

Resumo do fabricante

Texto original em inglês

TSB: Some 2019 ? 2020 model year Avalon Hybrid, Camry Hybrid, and RAV4 Hybrid vehicles may exhibit a MIL ON condition with a ?Hybrid System Malfunction? message displayed and one or more of the following DTC(s) that represent an over current between the MG1, MG2, and inverter/PCU: ?P1C5D19 ? Drive Motor "A" Inverter Circuit Current Above Threshold ?P1C5F19 ? Generator Inverter Circuit Current Above Threshold These conditions typically occur on low vehicle mileage (less than 5,000). After an occurrence, the vehicle will be able to run normally with no drivability issues. Follow the Repair Procedure in this bulletin to address these conditions

Comunicados da NHTSA ↗

Códigos no documento

Confira a aplicação ao veículo

A relação com um veículo é uma pista. Confirme motor, produção e software na documentação do fabricante.

MarcaModeloAno-modelo
ToyotaAVALON HYBRID2020
ToyotaAVALON HYBRID2019
ToyotaCAMRY HYBRID2020
ToyotaCAMRY HYBRID2019
ToyotaRAV4 HYBRID2020
ToyotaRAV4 HYBRID2019

Cobertura dos dados →