홈LI54.10-P-080684 · MERCEDES-BENZ
MERCEDES-BENZ

LI54.10-P-080684

제조사 기술 자료

발행일
2026-09-17
NHTSA 접수일
2026-10-06
NHTSA 기록 번호
11038181

제조사 요약

영어 원문

Complaint When disconnecting or connecting the charging connector, the charging socket flashes red and red warning messages are displayed in the instrument cluster. Immediately after that, neither driving nor charging is possible. Cause P292900: Contact 'Negative terminal' of contactor B in the high‐voltage battery is jammed closed If the charging cable connector is removed approximately 5 to 7 seconds after the charging process has ended, a fault is triggered. Remedy If this fault occurs, please follow these steps: 1) Wait for bus idle ‐> driving should be possible again. Note: Charging is still not possible. The fault will keep recurring as long as the fault is stored in the fault memory. 2) Plug in charging cable and check if fault (P292900 or P0AE173) is active. Clear active fault. Charging should be possible after the fault has been cleared. To prevent the fault from recurring, after the charging process has ended, wait at least 15 seconds before disconnecting the AC charging cable connector. Please create a TIPS case including quick test and HV control module log.

NHTSA 제조사 자료 ↗

원문 코드 표기

적용 차량 확인

목록의 차량은 조사 단서입니다. 제조사 자료에서 엔진, 생산 기간, 소프트웨어 조건을 확인하세요.

제조사모델연식
Mercedes-BenzG 580 E2027
Mercedes-BenzG 580 E2026

자료 범위 →