영어 원문
Charging starts and stops when using a public charging unit. Customer statement / workshop findings: When using a public charging unit to charge the high voltage battery, charging starts and is then interrupted/stops Workshop findings The following DTC is also evident: P33E800: Charge socket A, charge connector lock mechanical malfunction passive/sporadic. Measure: 1) Referring to Rep.Gr 93 - Carry out an Inspection and classification of the Hybrid battery unit AX1 VERY IMPORTANT: In the event that the classification result of the battery is Normal the operative should conduct the remaining steps of this TPI from step 2 However If the classification result of the battery is either Danger or Warning then move the car to the quarantine area and raise a DISS immediately, the operative MUST NOT continue with any other work unless instructed via the open DISS query 2) Check the operation of the charging system using the customers and the retailers own charging equipment 3) Run a full diagnostic log and check if the DTC within the Technical background section are evident.
원문 코드 표기
적용 차량 확인
목록의 차량은 조사 단서입니다. 제조사 자료에서 엔진, 생산 기간, 소프트웨어 조건을 확인하세요.
| 제조사 | 모델 | 연식 |
|---|---|---|
| Bentley | BENTAYGA HYBRID | 2022 |
| Bentley | BENTAYGA HYBRID | 2021 |
| Bentley | BENTAYGA HYBRID | 2020 |
| Bentley | FLYING SPUR | 2022 |