홈08-104-20 REV. A · ALFA ROMEO
ALFA ROMEO

08-104-20 REV. A

제조사 기술 자료

발행일
2020-12-18
NHTSA 접수일
2021-03-01
NHTSA 기록 번호
10187712

제조사 요약

영어 원문

Flash: Drive Style Control Module (DSCM) Updates This bulletin involves checking if the vehicle dynamic (DNA) selector is operable and possibly reprogramming the DSCM with the latest available software. Customers may experience a Malfunction Indicator Lamp (MIL) illumination. Upon further investigation the technician may find that one or more of the following Diagnostic Trouble Codes (DTCs) have been set: U1700-87 - Body Control Module (BCM) - Missing Message. U0011-14 - Down Rotary Knob Failure-Circuit Short To Ground Or Open. U0011-15 - Down Rotary Knob Failure-Circuit Short To Battery Or Open. U0012-14 - Up Rotary Knob Failure-Circuit Short To Ground Or Open. U0012-15 - Up Rotary Knob Failure-Circuit Short To Battery Or Open. B1603-68 - Rotary Encoder Fault-Event Information. The following DTC has been set in the Body Control Module (BCM):U1A18-87 - DSCM (Drive Style Control Module) - Missing Message. The customer may also comment on the following:The vehicle dynamic (DNA) selector is inoperable.

NHTSA 제조사 자료 ↗

원문 코드 표기

제조사 자료의 표현

차량과 접미 문자에 따라 다를 수 있습니다. 원문 표현이며 공통 진단이 아닙니다.

적용 차량 확인

목록의 차량은 조사 단서입니다. 제조사 자료에서 엔진, 생산 기간, 소프트웨어 조건을 확인하세요.

제조사모델연식
Alfa RomeoGIULIA2020

자료 범위 →