ホームLI54.21-P-079255 · MERCEDES-BENZ
MERCEDES-BENZ

LI54.21-P-079255

メーカー技術情報

発行日
2026-01-31
NHTSA 受理日
2026-01-31
NHTSA 記録番号
11027903

メーカー概要

英語の原文

Complaint Combustion engine does not start, MIL (Malfunction Indication Light) may light up in instrument cluster, only electric driving possible. Fault code P0E2F00 logged in control unit BMS N82/10. Cause Auxiliary consumer fuse in the HV battery has an open circuit, caused by a short circuit in the auxiliary consumer line. Remedy Requirement: Before carrying out test work, it must be ensured that the person performing the work has successfully completed the required qualification for work on the high-voltage system. Qualification according to WIS is required to replace the auxiliary consumer fuse including eLearning T3057D-US.TTB. Note: If the fault "P0E2F00 The electrical fuse B for the high voltage has a malfunction" is stored in the N82/10 BMS control unit, the HV protocol must also be checked to see whether the fuse for the auxiliary consumers is ok. Check: To determine the causing HV component in the auxiliary consumer line, please follow and process the guided troubleshooting of the fault "P0E2F00 The electrical fuse B for the high voltage has a malfunction" saved in the N82/10 BMS control unit.

NHTSA メーカー資料 ↗

原文のコード表記

対象車両を確認

掲載車両は調査の手がかりです。エンジン、製造期間、ソフトウェア条件はメーカー資料で確認してください。

メーカー車種モデル年
Mercedes-BenzAMG S 63 E 4MATIC+2025
Mercedes-BenzAMG S 63 E 4MATIC+2024
Mercedes-BenzAMG S 63 E 4MATIC+2023

資料の対象範囲 →