ホーム2066502/1 · BENTLEY
BENTLEY

2066502/1

メーカー技術情報

発行日
2022-03-23
NHTSA 受理日
2022-04-07
NHTSA 記録番号
10210076

メーカー概要

英語の原文

Charging starts and stops when using a public charging unit. Customer statement / workshop findings: When using a public charging unit to charge the high voltage battery, charging starts and is then interrupted/stops Workshop findings The following DTC is also evident: P33E800: Charge socket A, charge connector lock mechanical malfunction passive/sporadic. Measure: 1) Referring to Rep.Gr 93 - Carry out an Inspection and classification of the Hybrid battery unit AX1 VERY IMPORTANT: In the event that the classification result of the battery is Normal the operative should conduct the remaining steps of this TPI from step 2 However If the classification result of the battery is either Danger or Warning then move the car to the quarantine area and raise a DISS immediately, the operative MUST NOT continue with any other work unless instructed via the open DISS query 2) Check the operation of the charging system using the customers and the retailers own charging equipment 3) Run a full diagnostic log and check if the DTC within the Technical background section are evident.

NHTSA メーカー資料 ↗

原文のコード表記

対象車両を確認

掲載車両は調査の手がかりです。エンジン、製造期間、ソフトウェア条件はメーカー資料で確認してください。

メーカー車種モデル年
BentleyBENTAYGA HYBRID2022
BentleyBENTAYGA HYBRID2021
BentleyBENTAYGA HYBRID2020
BentleyFLYING SPUR2022

資料の対象範囲 →