ホームM120113 · MINI
MINI

M120113

メーカー技術情報

発行日
2013-02-01
NHTSA 受理日
2018-11-26
NHTSA 記録番号
10149464

メーカー概要

英語の原文

"N16 Engine: FC 2D9B Knock Sensor, Signal Is Stored in the DME. Certain areas of the US experience extremely cold climate conditions during the winter months, which can cause the Service Engine Soon lamp to illuminate while the engine temperature is increasing to full operating temperature. The following fault may be stored in the DME: FC 2D9B Knock Sensor, Signal While performing test plan B1214 M KNOCK SENSOR, the following error message will be displayed: ""An error has occurred during execution of a service program. Fault code: 61/3."" This error in the test plan will not allow diagnosis to continue. The test plan error will be repaired with ISTA/D 2.36.0. CAUSE A DME calibration error in the knock sensor diagnostics results in an increased sensitivity threshold to cold temperatures."

NHTSA メーカー資料 ↗

原文のコード表記

対象車両を確認

掲載車両は調査の手がかりです。エンジン、製造期間、ソフトウェア条件はメーカー資料で確認してください。

メーカー車種モデル年
MINICOOPER S CONVERTIBLE2011
MINICOOPER S CONVERTIBLE2010
MINICOOPER S US2011
MINICOOPER S US2009
MINICOOPER US2009
MINICOOPER US2007
MINIJCW CONVERTIBLE2012

資料の対象範囲 →